{"title":"Industrial Microwave Generator Repair, Servicing \u0026 For Sale","description":"\u003cp\u003eIndustrial microwave generators are used where reliable, repeatable heating matters most, and a high power microwave generator can be the difference between smooth production and costly downtime. Pentalabs supports customers who need new units, replacement systems, service, and repair help for demanding industrial microwave applications across food processing and other high-power operating environments.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 32px; margin-top: 15px;\"\u003eIndustrial microwave generators for sale\u003c\/h2\u003e\n\u003cp\u003ePentalabs supplies industrial microwave generator solutions for customers who need dependable microwave power for production, processing, and system replacement. That can include support for new requirements, replacement units for aging systems, and guidance when an existing setup no longer delivers the output, control, or reliability your operation needs.\u003c\/p\u003e\n\u003cp\u003eThese systems are used across a wide range of applications. In food processing, industrial microwave power may be used for tempering, thawing, defrosting, drying, boosting, and pre-heating. Common examples include meat and poultry tempering, bacon cooking, grain drying, fish preheating, potato product drying, snack food processing, and pizza topping preparation. Outside food production, microwave systems are also used in processes involving wood laminates, pellets, forest products, sandcasting cores, rubber vulcanization, foam curing, and waste material or sludge treatment.\u003c\/p\u003e\n\u003cp\u003eBecause real-world systems are rarely one-size-fits-all, this page should not imply that every customer needs the same configuration. Some operations may be looking for a 915 MHz microwave generator for deeper industrial heating applications, while others may require support around 896 MHz, 922 MHz, or 2450 MHz systems, depending on the process, product, and equipment design involved. In the same way, power requirements vary by workload and line design. One customer may be sourcing a 75kW microwave generator for an established production line, while another may be reviewing higher-output options, including 100kW microwave generators, for larger-scale or more demanding applications.\u003c\/p\u003e\n\u003cp\u003ePentalabs also works within the wider ecosystem around these systems. That matters because customers often do not just need a generator in isolation. They may also need related components, replacement assemblies, or help diagnosing which surrounding parts are contributing to poor performance. Depending on the setup, that could involve a \u003ca href=\"https:\/\/pentalabs.com\/collections\/magnetrons\"\u003emagnetron\u003c\/a\u003e, matching power hardware, or microwave line components that affect how efficiently the system operates.\u003c\/p\u003e\n\u003cp\u003eFor operations tied to frozen product handling and process-line heating, there may also be a close relationship between generator requirements and \u003ca href=\"https:\/\/pentalabs.com\/collections\/food-tempering\"\u003eindustrial microwave tempering\u003c\/a\u003e system needs. In many cases, the buying decision is not simply about replacing a failed box; it is about getting the right microwave power source for the exact process, throughput, and product characteristics involved.\u003c\/p\u003e","products":[{"product_id":"2j55","title":"2J55 X-Band Pulsed Magnetron","description":"\u003ch2 data-sourcepos=\"3:1-3:383\"\u003eThe 2J55 is a robust and reliable X-band pulsed magnetron, renowned for its compact design, high stability, and exceptional adaptability across a wide range of radar applications.\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for demanding environments, this electron tube delivers precise and powerful microwave pulses, making it a cornerstone for marine navigation, search radars, and other critical pulsed radar systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for consistent performance, the 2J55 ensures optimal operation in challenging conditions, offering a critical component for systems requiring high peak power output and stable frequency.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eFixed Frequency Operation:\u003c\/b\u003e Optimized for a precise frequency range in the X-band (typically 9345 to 9405 MHz), ensuring reliable signal generation for dedicated radar applications.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eHigh Peak Power Output:\u003c\/b\u003e Capable of delivering a substantial peak output power, commonly rated at 40 kW (peak), with some variants reaching up to 50 kW, providing strong signal returns for effective detection.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003ePulsed Operation:\u003c\/b\u003e Engineered for pulsed applications, the 2J55 is designed for short, high-energy bursts, crucial for accurate range and bearing measurements in radar systems.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eCompact Construction:\u003c\/b\u003e Its compact form factor facilitates integration into various radar system designs, offering flexibility in equipment layout.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eIntegral Magnet:\u003c\/b\u003e Features an integral magnet for a self-contained unit, simplifying installation and ensuring stable magnetic fields for consistent performance.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eWaveguide Output:\u003c\/b\u003e Equipped with a WR84 output connector\/waveguide, ensuring efficient and standard interfacing with radar system components.\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eForced Air Cooled:\u003c\/b\u003e Designed for forced air cooling, effectively managing heat dissipation to maintain optimal operating temperatures and extend tube life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eTypical Applications:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003eMarine Navigation Radars\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003eSearch Radars\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003eWeather Radars\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003eCoastal Surveillance Systems\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003eIndustrial Microwave Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eType:\u003c\/b\u003e Fixed Frequency Pulsed Magnetron\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eFrequency Range:\u003c\/b\u003e 9345 to 9405 MHz (X-band)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003ePeak Anode Voltage:\u003c\/b\u003e 11 to 13 kV (Peak)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003ePeak Anode Current:\u003c\/b\u003e 3.5 to 16 A\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eHeater Voltage:\u003c\/b\u003e 5.7 to 6.9 V (typically 6.3V)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eHeater Current:\u003c\/b\u003e 0.9 to 1.2 A\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003ePeak Output Power:\u003c\/b\u003e 40 kW (Peak) minimum (some variants up to 50 kW)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eDuty Cycle:\u003c\/b\u003e 0.001 (maximum)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003ePulse Width:\u003c\/b\u003e Up to 2.5 µs\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eVSWR at Output Coupler:\u003c\/b\u003e 1.5:1 (maximum)\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eAnode Temperature (Max):\u003c\/b\u003e 100 °C\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eOutput Connector\/Waveguide:\u003c\/b\u003e WR84\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eCooling:\u003c\/b\u003e Forced Air Cooled\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003eWeight:\u003c\/b\u003e Approximately 1.9 kg (4 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p1\"\u003eThe 2J55 X-Band Pulsed Magnetron represents a reliable and high-performance solution for professionals and industries demanding precise and powerful microwave generation in their radar systems.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eContact us for quotation.\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":45638782648564,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/PENTA_PRODUCT_HOLDER.png?v=1752876103"},{"product_id":"75-kw-l-band-cw-magnetron-tube-cwm-75","title":"CWM-75kW L-Band CW Magnetron Tube","description":"\u003ch3 data-sourcepos=\"7:1-7:272\"\u003e\n\u003cspan class=\"citation-1 recitation citation-end-1\"\u003eThis powerful L-band magnetron provides a continuous 75 kW of output power at 915 MHz, enabling rapid and efficient processing.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-2 recitation citation-end-2\"\u003eAchieve remarkable energy savings with up to 90% efficiency, minimizing operational costs while maximizing throughput.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-92 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-92\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-92\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-92 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"9:1-9:43\"\u003e\u003cstrong\u003eKey Features for Industrial Excellence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"11:1-18:0\"\u003e\n\u003cli data-sourcepos=\"11:1-11:106\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-3 recitation\"\u003eHigh Power Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-3 recitation citation-end-3\"\u003e 75 kW continuous wave (CW) power for demanding industrial processes.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-93 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-93\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-93\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-93 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:97\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-4 recitation\"\u003eL-Band Frequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-4 recitation citation-end-4\"\u003e Operates at 915 MHz, 922, 929, and 896MHz ideal for a wide range of applications.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-94 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-94\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-94\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-94 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-13:95\"\u003e\n\u003cstrong\u003eExceptional Efficiency:\u003c\/strong\u003e \u003cspan class=\"citation-5 recitation citation-end-5\"\u003eUp to 90% efficiency for reduced energy consumption.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-95 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-95\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-95\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-95 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"14:1-14:76\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-6 recitation\"\u003eFixed-Tuned Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-6 recitation citation-end-6\"\u003e Stable and reliable frequency output.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-96 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-96\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-96\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-96 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"15:1-15:95\"\u003e\n\u003cstrong\u003eMagnetically Focused:\u003c\/strong\u003e \u003cspan class=\"citation-7 recitation citation-end-7\"\u003ePrecise electron beam control for optimal performance.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-97 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-97\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-97\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-97 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"16:1-16:115\"\u003e\n\u003cstrong\u003eAir \u0026amp; Liquid Cooled:\u003c\/strong\u003e \u003cspan class=\"citation-8 recitation citation-end-8\"\u003eRobust cooling system for extended operation in demanding environments.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-98 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-98\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-98\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-98 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"17:1-18:0\"\u003e\n\u003cstrong\u003eCeramic-Metal Construction:\u003c\/strong\u003e Durable and reliable for long service life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"19:1-19:45\"\u003e\u003cstrong\u003eVersatile Applications Across Industries:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"21:1-25:0\"\u003e\n\u003cli data-sourcepos=\"21:1-21:165\"\u003e\n\u003cstrong\u003eFood Processing:\u003c\/strong\u003e \u003cspan class=\"citation-9 recitation citation-end-9\"\u003eThawing, cooking, preservation (sterilization, pasteurization, drying) for meats, poultry, pre-cooked meals, and bakery products.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-99 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-99\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-99\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-99 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"22:1-22:256\"\u003e\n\u003cstrong\u003eIndustrial Materials:\u003c\/strong\u003e \u003cspan class=\"citation-10 recitation citation-end-10\"\u003eDrying and curing of carbon black, clay, ceramics, wood, composites, filter materials, and casting molds.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-11 recitation citation-end-11\"\u003eChemical and thermal processes like polymer curing, metal sintering, and rubber vulcanization.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-100 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-100\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-100\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-100 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-100 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"23:1-23:162\"\u003e\n\u003cstrong\u003eAdvanced Materials:\u003c\/strong\u003e \u003cspan class=\"citation-12 recitation citation-end-12\"\u003eSynthesis and conversion, CVD diamond production, gas reforming, waste pyrolysis, and semiconductor annealing and doping.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-101 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-101\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-101\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-101 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"24:1-25:0\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-13 recitation\"\u003eMining \u0026amp; Minerals:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-13 recitation citation-end-13\"\u003e Ore benefaction through selective fracturing.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-102 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-102\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-102\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-102 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"26:1-26:69\"\u003e\u003cstrong\u003eExtend the Life of Your Magnetron with Our Core Exchange Program:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"28:1-28:273\"\u003e\u003cspan class=\"citation-14 recitation citation-end-14\"\u003ePenta Labs offers a comprehensive RF Core Exchange Refurbishment Program, designed to extend the service life of your Continuous Wave Magnetron.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e Contact us today for information on our refurbished Machlett Microwave CWM-75kW and CWM-100kW Magnetron Tube options.\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c!----\u003e\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cdiv class=\"container ng-tns-c3928559184-103 hide\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"carousel-container ng-tns-c3928559184-103\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c3928559184-103\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c3928559184-103 hide ng-star-inserted\"\u003e\u003c!----\u003e\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"30:1-30:158\"\u003e\u003cstrong\u003eInvest in the Machlett Microwave CWM-75kW Magnetron and elevate your industrial processing capabilities with unmatched power, efficiency, and reliability.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":45767913308404,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/PENTA_MCM75915_01_f9c7ecfd-3ec0-4099-9337-799c1d9c0ce7.jpg?v=1726171507"},{"product_id":"x-band-2000kw-mag-tube","title":"X BAND 2000KW Magnetron Tube","description":"\u003cp\u003ePenta Laboratories X BAND 2000KW Magnetron Tube\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e100% USA Made\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact us for pricing\u003c\/strong\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":45772463571188,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/PENTA_PRODUCT_HOLDER.png?v=1752876103"},{"product_id":"100-kw-l-band-cw-magnetron-tube-cwm-100-machlett-microwave","title":"CWM-100 100 kW L-Band CW Magnetron Tube","description":"\u003ch3\u003e\u003cstrong\u003eMachlett Microwave CWM-100kW Magnetron – Unmatched Power \u0026amp; Efficiency for Industrial Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eThe Machlett Microwave CWM-100kW\u003c\/strong\u003e is a state-of-the-art, fixed-tuned magnetron tube designed to meet the demanding requirements of industrial processing applications.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThis powerful L-band magnetron delivers a continuous 100 kW of output power at 915 MHz, with exceptional efficiency.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eHigh Power Output: 100 kW continuous wave (CW) power for demanding industrial processes\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eL-Band Frequency: Operates at 915 MHz, ideal for a wide range of applications\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eExceptional Efficiency: Up to 90% efficiency for reduced energy consumption\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eFixed-Tuned Design: Stable and reliable frequency output\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eMagnetically Focused: Precise electron beam control for optimal performance\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eAir \u0026amp; Liquid Cooled: Robust cooling system for extended operation in demanding environments\u003c\/div\u003e\n\u003cdiv\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003eCeramic-Metal Construction: Durable and reliable for long service life\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eApplications by Industry:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFood Processing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eThawing: Frozen meats, poultry, etc.\u003c\/div\u003e\n\u003cdiv\u003eCooking: Bacon, pre-cooked meals, etc.\u003c\/div\u003e\n\u003cdiv\u003ePreservation: Sterilization, pasteurization, drying (bakery, foodstuffs)\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eIndustrial Materials\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eDrying \u0026amp; Curing: Carbon black, clay, ceramics, wood, composites, filter materials, casting molds, etc.\u003c\/div\u003e\n\u003cdiv\u003eChemical \u0026amp; Thermal Processes: Polymer curing, metal sintering, rubber vulcanization\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eAdvanced Materials\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eSynthesis \u0026amp; Conversion: CVD diamond, gas reforming, waste pyrolysis\u003c\/div\u003e\n\u003cdiv\u003eSemiconductor: Annealing, doping\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMining \u0026amp; Minerals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eOre Beneficiation: Selective fracturing\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMagnetron Core Exchange Refurbishment Program\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003ePenta Labs provides RF Core Exchange Refurbishment Capability to extend the service life of your Machlett Microwave Continuous Wave Magnetron. Please contact us for information about refurbished Machlett Microwave CWM-75kW \u0026amp; 100kW Magnetron Tube options.\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":45814259712244,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MACHLETT_MCM75915_01.jpg?v=1726171579"},{"product_id":"machlett-transformer","title":"Machlett Microwave High Voltage Transformer","description":"\u003cp\u003e\u003cspan\u003eWhether you need service for existing machinery or replacement parts from OEM brands like Machlett Microwave,\u003c\/span\u003e\u003cspan\u003eFerrite,\u003c\/span\u003e\u003cspan\u003e Amana,\u003c\/span\u003e\u003cspan\u003e Raytheon,\u003c\/span\u003e\u003cspan\u003e Tempersol,\u003c\/span\u003e\u003cspan\u003e Selo-Bollans,\u003c\/span\u003e\u003cspan\u003e Pacific Wood Tech,\u003c\/span\u003e\u003cspan\u003e Forsstrom,\u003c\/span\u003e\u003cspan\u003e Thermex-Thermatron,\u003c\/span\u003e\u003cspan\u003e Thermo Wave,\u003c\/span\u003e\u003cspan\u003eMega RF,\u003c\/span\u003e\u003cspan\u003e or AMTek,\u003c\/span\u003e\u003cspan\u003e Penta Labs has the solutions you need.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eContact us for pricing\u003c\/span\u003e\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":45828345364724,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/PENTA_TRANSFORMER.jpg?v=1725671839"},{"product_id":"mg5193-tunable-s-band-magnetron","title":"MG5193 Tunable S-band Magnetron","description":"\u003ch3 data-sourcepos=\"3:1-3:43\"\u003eDesigned for Linear Accelerator (LINAC) Service.\u003c\/h3\u003e\n\u003ch3 data-sourcepos=\"5:1-5:311\"\u003e\n\u003cspan class=\"citation-0 recitation citation-end-0\"\u003eThe MG5193 is a high-power, mechanically tunable pulse magnetron specifically designed for use in linear accelerators.\u003c\/span\u003e Offering exceptional performance and reliability, the MG5193 is an ideal choice for demanding applications requiring precise frequency control and high peak output power.\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"container ng-tns-c1466767559-63 hide\"\u003e\n\u003cdiv class=\"carousel-container ng-tns-c1466767559-63\"\u003e\n\u003ch4 class=\"carousel-content ng-tns-c1466767559-63\"\u003e\u003cspan\u003e\u003cb\u003eEquivalent Replacement for E2V Teledyne MG5193 Tunable S-band Magnetron\u003c\/b\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-sourcepos=\"1:1-1:17\"\u003e\u003cstrong\u003eMG5193 Magnetron:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"3:1-5:41\"\u003e\n\u003cli data-sourcepos=\"3:1-3:37\"\u003eCL: CL4\/100, 6\/100, 600C, 6X, 6EX\u003c\/li\u003e\n\u003cli data-sourcepos=\"4:1-4:42\"\u003eVarian Part Number: 854876-01 (MG6165)\u003c\/li\u003e\n\u003cli data-sourcepos=\"5:1-5:41\"\u003eSiemens Part Number: 7992563 (MG6250)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"carousel-content ng-tns-c1466767559-63\"\u003e\n\u003cspan\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"carousel-content ng-tns-c1466767559-63\"\u003e\u003cspan\u003e\u003cb\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul data-sourcepos=\"10:1-16:0\"\u003e\n\u003cli data-sourcepos=\"10:1-10:58\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-1 recitation\"\u003eWide Frequency Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-1 recitation citation-end-1\"\u003e 2993 to 3002 MHz\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:49\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-2 recitation\"\u003eHigh Peak Output Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-2 recitation citation-end-2\"\u003e 2.6 MW\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:92\"\u003e\n\u003cstrong\u003eMechanical Tuning:\u003c\/strong\u003e Allows for precise frequency adjustment within the specified range.\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-13:94\"\u003e\n\u003cstrong\u003eWater Cooling:\u003c\/strong\u003e Ensures efficient heat dissipation for optimal performance and longevity.\u003c\/li\u003e\n\u003cli data-sourcepos=\"14:1-14:99\"\u003e\n\u003cstrong\u003eVersatile Mounting:\u003c\/strong\u003e Can be mounted in any position for easy integration into various systems.\u003c\/li\u003e\n\u003cli data-sourcepos=\"15:1-16:0\"\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Built to withstand the rigors of industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"1:1-1:23\"\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"3:1-14:0\"\u003e\n\u003cli data-sourcepos=\"3:1-3:95\"\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e Covers 2993 to 3002 MHz, providing flexibility for various applications.\u003c\/li\u003e\n\u003cli data-sourcepos=\"4:1-4:90\"\u003e\n\u003cstrong\u003ePeak Output Power:\u003c\/strong\u003e Delivers up to 2.6 MW, making it suitable for high-power demands.\u003c\/li\u003e\n\u003cli data-sourcepos=\"5:1-5:92\"\u003e\n\u003cstrong\u003eCathode:\u003c\/strong\u003e Utilizes an indirectly heated cathode for enhanced performance and stability.\u003c\/li\u003e\n\u003cli data-sourcepos=\"6:1-6:63\"\u003e\n\u003cstrong\u003eHeater Voltage:\u003c\/strong\u003e Requires 8.5 volts for optimal operation.\u003c\/li\u003e\n\u003cli data-sourcepos=\"7:1-7:74\"\u003e\n\u003cstrong\u003eHeater Current:\u003c\/strong\u003e Operates at 9.0 amperes, ensuring efficient heating.\u003c\/li\u003e\n\u003cli data-sourcepos=\"8:1-8:78\"\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Employs water cooling to maintain ideal operating temperatures.\u003c\/li\u003e\n\u003cli data-sourcepos=\"9:1-9:85\"\u003e\n\u003cstrong\u003eOutput Coupling:\u003c\/strong\u003e Features a No. 10 waveguide (WR 284) for seamless integration.\u003c\/li\u003e\n\u003cli data-sourcepos=\"10:1-10:89\"\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e Weighs approximately 8 kg, offering a balance of power and portability.\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:94\"\u003e\n\u003cstrong\u003eMechanical Tuning:\u003c\/strong\u003e Allows for precise frequency adjustment within the operational range.\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-14:0\"\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Can be mounted in any orientation, providing installation flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"5:1-5:44\"\u003e\u003cstrong\u003eCompatible with a Wide Range of Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"7:1-7:91\"\u003eThis versatile magnetron is a perfect fit for various linear accelerator models, including:\u003c\/p\u003e\n\u003cul data-sourcepos=\"9:1-14:0\"\u003e\n\u003cli data-sourcepos=\"9:1-9:41\"\u003eSiemens systems (Siemens Part #5845172)\u003c\/li\u003e\n\u003cli data-sourcepos=\"10:1-10:18\"\u003eOlder Tomo units\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:16\"\u003eElekta Compact\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:15\"\u003eVarian Unique\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-14:0\"\u003eETM cargo scanning systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":45981207724276,"sku":"","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MG5193.png?v=1732315421"},{"product_id":"mg6090-tunable-s-band-magnetron","title":"MG6090 Tunable S-Band Magnetron","description":"\u003ch3 data-sourcepos=\"5:1-5:237\"\u003e\u003cspan\u003eThe MG6090 is a tunable S-band pulse magnetron designed for LINAC use in Siemens, Varian Unique, and Radixact linear accelerators. It offers a peak output power of 3 MW and a mechanically tunable frequency range from 2993 to 3002 MHz.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVarian Part Number:\u003c\/strong\u003e 10001301301\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-sourcepos=\"1:1-1:25\"\u003e\n\u003cstrong\u003eMagnetron:\u003c\/strong\u003e MG6090\u003c\/li\u003e\n\u003cli data-sourcepos=\"2:1-2:24\"\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e MG5349\u003c\/li\u003e\n\u003cli data-sourcepos=\"3:1-3:47\"\u003e\n\u003cstrong\u003eVarian Part Number:\u003c\/strong\u003e 1102173-02 (MG6190)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003eEquivalent Replacement for E2V Teledyne MG6090 Tunable S-Band Magnetron\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"7:1-7:32\"\u003e\u003cstrong\u003e2. Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"9:1-21:0\"\u003e\n\u003cli data-sourcepos=\"9:1-9:39\"\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 2993 to 3002 MHz\u003c\/li\u003e\n\u003cli data-sourcepos=\"10:1-10:29\"\u003e\n\u003cstrong\u003ePeak Output Power:\u003c\/strong\u003e 3 MW\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:43\"\u003e\n\u003cstrong\u003eAnode Voltage (peak):\u003c\/strong\u003e 52 kV (typical)\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:43\"\u003e\n\u003cstrong\u003eAnode Current (peak):\u003c\/strong\u003e 102 A (typical)\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-13:38\"\u003e\n\u003cstrong\u003ePulse Duration:\u003c\/strong\u003e 4.3 μs (typical)\u003c\/li\u003e\n\u003cli data-sourcepos=\"14:1-14:54\"\u003e\n\u003cstrong\u003ePulse Repetition Rate:\u003c\/strong\u003e 50 to 405 p.p.s (typical)\u003c\/li\u003e\n\u003cli data-sourcepos=\"15:1-15:56\"\u003e\n\u003cstrong\u003eRate of Rise of Voltage Pulse:\u003c\/strong\u003e 120 kV\/μs (typical)\u003c\/li\u003e\n\u003cli data-sourcepos=\"16:1-21:0\"\u003e\n\u003cstrong\u003eCathode:\u003c\/strong\u003e Indirectly heated\n\u003cul data-sourcepos=\"17:5-21:0\"\u003e\n\u003cli data-sourcepos=\"17:5-17:32\"\u003e\n\u003cstrong\u003eHeater Voltage:\u003c\/strong\u003e 14 Vdc\u003c\/li\u003e\n\u003cli data-sourcepos=\"18:5-18:41\"\u003e\n\u003cstrong\u003eHeater Current (at 14 V):\u003c\/strong\u003e 8.0 A\u003c\/li\u003e\n\u003cli data-sourcepos=\"19:5-19:47\"\u003e\n\u003cstrong\u003eMaximum Heater Starting Current:\u003c\/strong\u003e 20 A\u003c\/li\u003e\n\u003cli data-sourcepos=\"20:5-21:0\"\u003e\n\u003cstrong\u003eCathode Pre-heating Time:\u003c\/strong\u003e 10 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"22:1-22:32\"\u003e\u003cstrong\u003e3. Mechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"24:1-29:0\"\u003e\n\u003cli data-sourcepos=\"24:1-24:96\"\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e Refer to dimensional data provided (page 5 of the product information)\u003c\/li\u003e\n\u003cli data-sourcepos=\"25:1-25:47\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-0 recitation\"\u003eNet Weight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-0 recitation citation-end-0\"\u003e 8.6 kg (approx.)\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003cdiv class=\"container ng-tns-c1466767559-106 hide\"\u003e\n\u003cdiv class=\"carousel-container ng-tns-c1466767559-106\"\u003e\n\u003cdiv class=\"carousel-content ng-tns-c1466767559-106\"\u003e\n\u003cdiv data-test-id=\"sources-carousel-source\" class=\"sources-carousel-source ng-tns-c1466767559-106 hide ng-star-inserted\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"26:1-26:54\"\u003e\n\u003cstrong\u003eTuner Revolutions to Cover Frequency Range:\u003c\/strong\u003e 5.75\u003c\/li\u003e\n\u003cli data-sourcepos=\"27:1-27:28\"\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Any\u003c\/li\u003e\n\u003cli data-sourcepos=\"28:1-29:0\"\u003e\n\u003cstrong\u003eOutput Coupling:\u003c\/strong\u003e #10 Waveguide (72.14 x 34.04 mm internal)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"30:1-30:27\"\u003e\u003cstrong\u003e4. Cooling Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"32:1-39:0\"\u003e\n\u003cli data-sourcepos=\"32:1-35:42\"\u003e\n\u003cstrong\u003eAnode Cooling:\u003c\/strong\u003e Water\n\u003cul data-sourcepos=\"33:5-35:42\"\u003e\n\u003cli data-sourcepos=\"33:5-33:28\"\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 5 L\/min\u003c\/li\u003e\n\u003cli data-sourcepos=\"34:5-34:47\"\u003e\n\u003cstrong\u003ePressure Drop at 5 L\/min:\u003c\/strong\u003e 1.25 kg\/cm²\u003c\/li\u003e\n\u003cli data-sourcepos=\"35:5-35:42\"\u003e\n\u003cstrong\u003eMaximum Outlet Temperature:\u003c\/strong\u003e 50°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"36:1-37:39\"\u003e\n\u003cstrong\u003eCathode Cooling:\u003c\/strong\u003e Air\n\u003cul data-sourcepos=\"37:5-37:39\"\u003e\n\u003cli data-sourcepos=\"37:5-37:39\"\u003e\n\u003cstrong\u003eCathode Air Flow:\u003c\/strong\u003e 0.28 m³\/min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"38:1-39:0\"\u003e\n\u003cstrong\u003eMagnet:\u003c\/strong\u003e External (north seeking pole face adjacent to magnetron anode face)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"40:1-40:27\"\u003e\u003cstrong\u003e5. Operating Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"42:1-45:0\"\u003e\n\u003cli data-sourcepos=\"42:1-42:44\"\u003e\n\u003cstrong\u003eMagnetic Field:\u003c\/strong\u003e 165.0 to 242.5 ± 10 mT\u003c\/li\u003e\n\u003cli data-sourcepos=\"43:1-43:52\"\u003e\n\u003cstrong\u003eWaveguide Pressure:\u003c\/strong\u003e 3.1 kg\/cm² gauge (maximum)\u003c\/li\u003e\n\u003cli data-sourcepos=\"44:1-45:0\"\u003e\n\u003cstrong\u003eVSWR at the Output Coupler:\u003c\/strong\u003e 1.5:1 (maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"46:1-46:33\"\u003e\u003cstrong\u003e6. Test Conditions and Limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"48:1-65:0\"\u003e\n\u003cli data-sourcepos=\"48:1-55:50\"\u003e\n\u003cstrong\u003eTest Conditions:\u003c\/strong\u003e\n\u003cul data-sourcepos=\"49:5-55:50\"\u003e\n\u003cli data-sourcepos=\"49:5-49:40\"\u003e\n\u003cstrong\u003eMagnetic Field:\u003c\/strong\u003e 160.0 ± 0.5 mT\u003c\/li\u003e\n\u003cli data-sourcepos=\"50:5-50:40\"\u003e\n\u003cstrong\u003eHeater Voltage (for test):\u003c\/strong\u003e 0 V\u003c\/li\u003e\n\u003cli data-sourcepos=\"51:5-51:37\"\u003e\n\u003cstrong\u003eAnode Current (peak):\u003c\/strong\u003e 115 A\u003c\/li\u003e\n\u003cli data-sourcepos=\"52:5-52:42\"\u003e\n\u003cstrong\u003ePulse Repetition Rate:\u003c\/strong\u003e 200 p.p.s\u003c\/li\u003e\n\u003cli data-sourcepos=\"53:5-53:32\"\u003e\n\u003cstrong\u003ePulse Duration:\u003c\/strong\u003e 5.0 μs\u003c\/li\u003e\n\u003cli data-sourcepos=\"54:5-54:43\"\u003e\n\u003cstrong\u003eVSWR at the Output Coupler:\u003c\/strong\u003e 1.1:1\u003c\/li\u003e\n\u003cli data-sourcepos=\"55:5-55:50\"\u003e\n\u003cstrong\u003eRate of Rise of Voltage Pulse:\u003c\/strong\u003e 120 kV\/μs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"56:1-65:0\"\u003e\n\u003cstrong\u003eLimits:\u003c\/strong\u003e\n\u003cul data-sourcepos=\"57:5-65:0\"\u003e\n\u003cli data-sourcepos=\"57:5-57:43\"\u003e\n\u003cstrong\u003eAnode Voltage (peak):\u003c\/strong\u003e 46 to 52 kV\u003c\/li\u003e\n\u003cli data-sourcepos=\"58:5-58:47\"\u003e\n\u003cstrong\u003eOutput Power (peak):\u003c\/strong\u003e 3.0 MW (minimum)\u003c\/li\u003e\n\u003cli data-sourcepos=\"59:5-59:47\"\u003e\n\u003cstrong\u003eLower Limit of Tuning Range:\u003c\/strong\u003e 2993 MHz\u003c\/li\u003e\n\u003cli data-sourcepos=\"60:5-60:47\"\u003e\n\u003cstrong\u003eUpper Limit of Tuning Range:\u003c\/strong\u003e 3002 MHz\u003c\/li\u003e\n\u003cli data-sourcepos=\"61:5-61:43\"\u003e\n\u003cstrong\u003eRF Bandwidth (1⁄4 Power):\u003c\/strong\u003e 1.2 MHz\u003c\/li\u003e\n\u003cli data-sourcepos=\"62:5-62:63\"\u003e\n\u003cstrong\u003eFrequency Pulling (VSWR not less than 1.5:1):\u003c\/strong\u003e 7.0 MHz\u003c\/li\u003e\n\u003cli data-sourcepos=\"63:5-63:25\"\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e 0.5%\u003c\/li\u003e\n\u003cli data-sourcepos=\"64:5-65:0\"\u003e\n\u003cstrong\u003eHeater Current:\u003c\/strong\u003e Refer to Note 13 (7.0 A min, 9.0 A max with 14 Vdc heater voltage and no anode input power)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"66:1-66:22\"\u003e\u003cstrong\u003e7. Important Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"68:1-73:0\"\u003e\n\u003cli data-sourcepos=\"68:1-68:76\"\u003eIt is recommended to use a DC power supply for the heater to avoid damage.\u003c\/li\u003e\n\u003cli data-sourcepos=\"69:1-69:154\"\u003eThe heater voltage must be reduced within 5 seconds after applying high voltage, according to the schedule provided (page 4 of the product information).\u003c\/li\u003e\n\u003cli data-sourcepos=\"70:1-70:132\"\u003eThe magnetron heater requires protection against arcing using a capacitance of at least 4000 pF across the heater input terminals.\u003c\/li\u003e\n\u003cli data-sourcepos=\"71:1-71:68\"\u003eAn isolator is recommended to isolate the magnetron from the load.\u003c\/li\u003e\n\u003cli data-sourcepos=\"72:1-73:0\"\u003eRefer to the product information for detailed dimensional data, heater voltage reduction schedule, and recommended parameters for various power levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"74:1-74:25\"\u003e\u003cstrong\u003e8. Safety Precautions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"76:1-78:0\"\u003e\n\u003cli data-sourcepos=\"76:1-76:89\"\u003eThis product utilizes high voltages and should only be operated by qualified personnel.\u003c\/li\u003e\n\u003cli data-sourcepos=\"77:1-78:0\"\u003eFollow all safety guidelines and precautions outlined in the product information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"79:1-79:235\"\u003eThis product specification provides a summary of the key features and specifications of the MG6090 magnetron. For comprehensive information and operational details, please request a data sheet.\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":45981288071412,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MG6090.png?v=1733530451"},{"product_id":"cx1154l-thyratron","title":"CX1154L Hydrogen Filled Ceramic Thyratron","description":"\u003ch3 data-sourcepos=\"1:1-1:143\"\u003eThe EG\u0026amp;G CX1154L is a hydrogen-filled tetrode thyratron with a ceramic\/metal envelope, designed for demanding high-power switching applications needing a r\u003cb\u003eeplacement E2V Teledyne CX1154L Thyraton\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp data-sourcepos=\"1:1-1:143\"\u003e\u003cstrong\u003eIt offers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"3:1-6:0\"\u003e\n\u003cli data-sourcepos=\"3:1-3:124\"\u003e\n\u003cstrong\u003eFast recovery time, low jitter, firing time, and drift:\u003c\/strong\u003e Ensures precise and reliable performance in pulse modulation.\u003c\/li\u003e\n\u003cli data-sourcepos=\"4:1-4:135\"\u003e\n\u003cstrong\u003eImproved performance over the CX1154:\u003c\/strong\u003e Specifically developed for enhanced performance in magnetron and klystron pulse modulators.\u003c\/li\u003e\n\u003cli data-sourcepos=\"5:1-6:0\"\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Primarily designed for Elekta systems and ETM cargo scanning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"7:1-7:36\"\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e 5850867\u003c\/p\u003e\n\u003cp data-sourcepos=\"7:1-7:36\"\u003e\u003cstrong\u003eElekta Part Number:\u003c\/strong\u003e 45133165177 \u003c\/p\u003e\n\u003cp data-sourcepos=\"7:1-7:36\"\u003ePlease contact us for Data Sheet and Pricing\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":45981343482100,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/CX1154.png?v=1733873007"},{"product_id":"varian-mg6165-magnetron-oem-drop-in-replacement","title":"MG5193 \/ MG6165 Magnetron","description":"\u003cdiv class=\"container ng-tns-c1466767559-63 hide\"\u003e\n\u003cdiv class=\"carousel-container ng-tns-c1466767559-63\"\u003e\n\u003ch2 class=\"carousel-content ng-tns-c1466767559-63\"\u003e\u003cspan\u003e\u003cb\u003eEquivalent Replacement for E2V Teledyne MG6125 Tunable S-band Magnetron for MLINAC Service.\u003c\/b\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eHigh-power RF devices. OEM replacements. Competitive prices. That's Penta Labs. We deliver rigorously tested parts designed for performance and value. Our focus on the end-user experience means you get a best-in-class, affordable alternative, backed by a comprehensive warranty.\u003c\/h3\u003e\n\u003cp data-sourcepos=\"1:1-1:17\"\u003e\u003cstrong\u003eMG6125 \/ MG5193 Magnetron:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"3:1-5:41\"\u003e\n\u003cli data-sourcepos=\"3:1-3:37\"\u003eCL: CL4\/100, 6\/100, 600C, 6X, 6EX\u003c\/li\u003e\n\u003cli data-sourcepos=\"4:1-4:42\"\u003eVarian Part Number: 854876-01 (MG6165)\u003c\/li\u003e\n\u003cli data-sourcepos=\"5:1-5:41\"\u003eSiemens Part Number: 7992563 (MG6250)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"carousel-content ng-tns-c1466767559-63\"\u003e\u003cspan\u003e\u003cb\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul data-sourcepos=\"10:1-16:0\"\u003e\n\u003cli data-sourcepos=\"10:1-10:58\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-1 recitation\"\u003eWide Frequency Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-1 recitation citation-end-1\"\u003e 2993 to 3002 MHz\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:49\"\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-2 recitation\"\u003eHigh Peak Output Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-2 recitation citation-end-2\"\u003e 2.6 MW\u003c\/span\u003e\u003cspan class=\"button-container hide-from-message-actions ng-star-inserted\"\u003e   \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:92\"\u003e\n\u003cstrong\u003eMechanical Tuning:\u003c\/strong\u003e Allows for precise frequency adjustment within the specified range.\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-13:94\"\u003e\n\u003cstrong\u003eWater Cooling:\u003c\/strong\u003e Ensures efficient heat dissipation for optimal performance and longevity.\u003c\/li\u003e\n\u003cli data-sourcepos=\"14:1-14:99\"\u003e\n\u003cstrong\u003eVersatile Mounting:\u003c\/strong\u003e Can be mounted in any position for easy integration into various systems.\u003c\/li\u003e\n\u003cli data-sourcepos=\"15:1-16:0\"\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Built to withstand the rigors of industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"1:1-1:23\"\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-sourcepos=\"3:1-14:0\"\u003e\n\u003cli data-sourcepos=\"3:1-3:95\"\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e Covers 2993 to 3002 MHz, providing flexibility for various applications.\u003c\/li\u003e\n\u003cli data-sourcepos=\"4:1-4:90\"\u003e\n\u003cstrong\u003ePeak Output Power:\u003c\/strong\u003e Delivers up to 2.6 MW, making it suitable for high-power demands.\u003c\/li\u003e\n\u003cli data-sourcepos=\"5:1-5:92\"\u003e\n\u003cstrong\u003eCathode:\u003c\/strong\u003e Utilizes an indirectly heated cathode for enhanced performance and stability.\u003c\/li\u003e\n\u003cli data-sourcepos=\"6:1-6:63\"\u003e\n\u003cstrong\u003eHeater Voltage:\u003c\/strong\u003e Requires 8.5 volts for optimal operation.\u003c\/li\u003e\n\u003cli data-sourcepos=\"7:1-7:74\"\u003e\n\u003cstrong\u003eHeater Current:\u003c\/strong\u003e Operates at 9.0 amperes, ensuring efficient heating.\u003c\/li\u003e\n\u003cli data-sourcepos=\"8:1-8:78\"\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Employs water cooling to maintain ideal operating temperatures.\u003c\/li\u003e\n\u003cli data-sourcepos=\"9:1-9:85\"\u003e\n\u003cstrong\u003eOutput Coupling:\u003c\/strong\u003e Features a No. 10 waveguide (WR 284) for seamless integration.\u003c\/li\u003e\n\u003cli data-sourcepos=\"10:1-10:89\"\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e Weighs approximately 8 kg, offering a balance of power and portability.\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:94\"\u003e\n\u003cstrong\u003eMechanical Tuning:\u003c\/strong\u003e Allows for precise frequency adjustment within the operational range.\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-14:0\"\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Can be mounted in any orientation, providing installation flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-sourcepos=\"5:1-5:44\"\u003e\u003cstrong\u003eCompatible with a Wide Range of Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-sourcepos=\"7:1-7:91\"\u003eThis versatile magnetron is a perfect fit for various linear accelerator models, including:\u003c\/p\u003e\n\u003cul data-sourcepos=\"9:1-14:0\"\u003e\n\u003cli data-sourcepos=\"9:1-9:41\"\u003eSiemens systems (Siemens Part #5845172)\u003c\/li\u003e\n\u003cli data-sourcepos=\"10:1-10:18\"\u003eOlder Tomo units\u003c\/li\u003e\n\u003cli data-sourcepos=\"11:1-11:16\"\u003eElekta Compact\u003c\/li\u003e\n\u003cli data-sourcepos=\"12:1-12:15\"\u003eVarian Unique\u003c\/li\u003e\n\u003cli data-sourcepos=\"13:1-14:0\"\u003eETM cargo scanning systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/pentalabs.com\/pages\/request-a-quote\" title=\"RFQ for MG6165\"\u003eContact Us\u003c\/a\u003e for questions and technical specifications.\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":46192161882356,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MG5193.png?v=1732315421"},{"product_id":"e3327-high-performance-cw-magnetron","title":"E3327 \/ YJ1600 High-Performance CW Magnetron","description":"\u003ch2 data-start=\"1262\" data-end=\"1282\"\u003eE3327\/YJ1600 Tube Specs\u003c\/h2\u003e\n\u003cp data-start=\"1284\" data-end=\"1476\"\u003eThe E3327\/YJ1600 is engineered for long-life performance in continuous and pulsed RF applications. Below is a summary of general specifications of this high-quality vacuum tube. For detailed parameters, refer to the datasheet below.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1478\" data-end=\"2206\"\u003e\n\u003cthead data-start=\"1478\" data-end=\"1550\"\u003e\n\u003ctr data-start=\"1478\" data-end=\"1550\"\u003e\n\u003cth data-start=\"1478\" data-end=\"1506\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1497\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1506\" data-end=\"1550\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1508\" data-end=\"1519\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1623\" data-end=\"2206\"\u003e\n\u003ctr data-start=\"1623\" data-end=\"1695\"\u003e\n\u003ctd data-start=\"1623\" data-end=\"1651\" data-col-size=\"sm\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd data-start=\"1651\" data-end=\"1695\" data-col-size=\"sm\"\u003e30–60 kW (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1696\" data-end=\"1768\"\u003e\n\u003ctd data-start=\"1696\" data-end=\"1724\" data-col-size=\"sm\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd data-start=\"1724\" data-end=\"1768\" data-col-size=\"sm\"\u003eUp to 15,000 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1769\" data-end=\"1841\"\u003e\n\u003ctd data-start=\"1769\" data-end=\"1797\" data-col-size=\"sm\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd data-start=\"1797\" data-end=\"1841\" data-col-size=\"sm\"\u003e896 – 915 MHz (typically)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1842\" data-end=\"1914\"\u003e\n\u003ctd data-start=\"1842\" data-end=\"1870\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-start=\"1870\" data-end=\"1914\" data-col-size=\"sm\"\u003eForced air or water-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1915\" data-end=\"1987\"\u003e\n\u003ctd data-start=\"1915\" data-end=\"1943\" data-col-size=\"sm\"\u003eTube Type\u003c\/td\u003e\n\u003ctd data-start=\"1943\" data-end=\"1987\" data-col-size=\"sm\"\u003eCeramic\/metal microwave tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1988\" data-end=\"2060\"\u003e\n\u003ctd data-start=\"1988\" data-end=\"2016\" data-col-size=\"sm\"\u003eEnvelope Material\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2060\" data-col-size=\"sm\"\u003eMetal-ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2061\" data-end=\"2133\"\u003e\n\u003ctd data-start=\"2061\" data-end=\"2089\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2089\" data-end=\"2133\" data-col-size=\"sm\"\u003eRF heating, food tempering, drying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2134\" data-end=\"2206\"\u003e\n\u003ctd data-start=\"2134\" data-end=\"2162\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2162\" data-end=\"2206\" data-col-size=\"sm\"\u003eVaries by configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-start=\"2213\" data-end=\"2247\"\u003eE3327 Tube Data Sheet Download\u003c\/h3\u003e\n\u003cp data-start=\"2249\" data-end=\"2445\"\u003eNeed detailed technical specs? Download the complete \u003cstrong data-start=\"2302\" data-end=\"2327\"\u003eE3327 tube data sheet\u003c\/strong\u003e to review electrical ratings, mounting details, and application guidelines for safe and efficient system integration.\u003c\/p\u003e\n\u003cp data-start=\"2447\" data-end=\"2526\"\u003e📥 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/E3327-YJ1600.pdf?v=1766270093\" rel=\"noopener\" class=\"cursor-pointer\" data-start=\"2450\" data-end=\"2526\"\u003eDownload E3327 Datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"2667\" data-end=\"2717\"\u003eE3327\/YJ1600 Tube Substitute \u0026amp; Equivalent Information\u003c\/h3\u003e\n\u003cp data-start=\"2719\" data-end=\"3087\"\u003eThe \u003cstrong data-start=\"2723\" data-end=\"2748\"\u003eE3327\/YJ1600 tube equivalent\u003c\/strong\u003e is used across a wide range of RF and microwave-based systems. It is commonly found in high-power industrial applications including microwave drying, food processing lines, and rubber curing stations. This product can often serve as a substitute for similar microwave and RF tubes from other manufacturers, depending on system configuration.\u003c\/p\u003e\n\u003cp data-start=\"3089\" data-end=\"3497\"\u003ePenta Labs is one of the most trusted \u003ca href=\"https:\/\/pentalabs.com\/\" rel=\"noopener\" class=\"\" data-start=\"3127\" data-end=\"3184\"\u003eelectron tube manufacturers\u003c\/a\u003e, supplying parts worldwide to OEMs and industrial facilities. We also partner with leading \u003ca href=\"https:\/\/pentalabs.com\/collections\/magnetrons\" rel=\"noopener\" class=\"\" data-start=\"3276\" data-end=\"3351\"\u003emagnetron manufacturers\u003c\/a\u003e and stock a wide range of \u003ca href=\"https:\/\/pentalabs.com\/pages\/rf-and-microwave-components\" rel=\"noopener\" class=\"\" data-start=\"3378\" data-end=\"3468\"\u003eRF and microwave components\u003c\/a\u003e for complete system support.\u003c\/p\u003e\n\u003cp data-start=\"3499\" data-end=\"3701\"\u003eFor related components and RF solutions used in industrial microwave tempering systems, explore our \u003ca href=\"https:\/\/pentalabs.com\/collections\/food-tempering\" rel=\"noopener\" class=\"\" data-start=\"3603\" data-end=\"3689\"\u003eindustrial microwave tempering\u003c\/a\u003e collection.\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":46599745962228,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/PENTA_E3327.png?v=1750810803"},{"product_id":"mg7095","title":"MG7095 Magnetron","description":"\u003ch2 style=\"font-size: 32px; margin-top: 15px;\"\u003eMG7095 magnetron specs\u003c\/h2\u003e\n\u003cp\u003eThis MG7095 is an e2v magnetron designed for pulsed S-band operation with mechanical tuning and water cooling. If you are new to magnetrons, there’s a quick explainer on our \u003ca href=\"https:\/\/pentalabs.com\/blogs\/tube-talk\/what-is-a-magnetron\" rel=\"noopener\" target=\"_blank\"\u003ewhat is a magnetron\u003c\/a\u003e page to help explain the basics before you dive into the specifications.\u003c\/p\u003e\n\u003cp\u003eGeneral specifications are shown below; refer to the datasheet for full limits, test conditions, outlines, and integration notes.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 2px solid #000;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #000; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #000; padding: 10px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eDevice type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eMechanically tuned pulsed S-band magnetron (intended primarily for linear accelerators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e2993–3002 MHz (with specified cooling water conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003ePeak output power\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e3.1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eOutput interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eVia transition to WR284 waveguide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eWater-cooled (verify flow rate and outlet temperature limits per datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eAnode voltage (peak)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e46–52 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003ePeak anode current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e60–120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003ePulse duration (max)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eUp to 5.0 µs (confirm your modulator timing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eMagnet\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eSeparate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eApprox. net weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e~8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 32px; margin-top: 15px;\"\u003eMG7095 magnetron data sheet download\u003c\/h3\u003e\n\u003cp\u003eThe relevant datasheet download is below. Use it to confirm outline dimensions, cooling connections, recommended operating points, and any system integration notes before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MG7095.pdf?v=1770402162\"\u003e\u003cstrong\u003eDownload MG7095 datasheet (PDF)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 style=\"font-size: 32px; margin-top: 15px;\"\u003eMG7095 substitute \u0026amp; equivalent information\u003c\/h3\u003e\n\u003cp\u003eMagnetron substitutions should be treated as a fit-and-function exercise, not a “close enough” swap. In addition to matching frequency range and peak power, confirm the tuner range, waveguide transition, magnet arrangement, cooling requirements, and your modulator’s pulse width and rise-time behavior.\u003c\/p\u003e\n\u003cp\u003eIf you’re replacing an MG5193-family magnetron, you may see it discussed as an MG7095 equivalent in spares listings. Treat that as a starting point only—verify mechanical fit, cooling, and operating conditions against your system documentation or reach out to us for help.\u003c\/p\u003e\n\u003cp\u003eIf you’re troubleshooting the full high-voltage chain, you may also need a compatible \u003ca href=\"https:\/\/pentalabs.com\/collections\/transformers\" rel=\"noopener\" target=\"_blank\"\u003emagnetron transformer\u003c\/a\u003e rather than only swapping the RF source.\u003c\/p\u003e\n\u003cp\u003eIf your work is within a radiation therapy platform and you’re sourcing components across the same subsystem, you can also review our \u003ca href=\"https:\/\/pentalabs.com\/collections\/linac-radiation\" rel=\"noopener\" target=\"_blank\"\u003elinear accelerator parts\u003c\/a\u003e selection.\u003c\/p\u003e\n\u003cp\u003eFor broader model comparison and availability across related products, contact us with your specs and photos—as trusted \u003ca href=\"https:\/\/pentalabs.com\/collections\/magnetrons\"\u003emagnetron manufacturers\u003c\/a\u003e, we can help verify fit and compatibility across related models.\u003c\/p\u003e","brand":"Penta Laboratories","offers":[{"title":"Default Title","offer_id":47614202151156,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/6996\/7348\/files\/MG70951024x1024.jpg?v=1770674166"}],"url":"https:\/\/pentalabs.com\/collections\/microwave-generator.oembed","provider":"Penta Laboratories","version":"1.0","type":"link"}